LUTRON MVB-385SD VIBRATION DATA RECORDER

banner

LUTRON MVB-385SD VIBRATION DATA RECORDER

Brand

LUTRON

รุ่น

MVB-385SD

Download Documents

Product Manual : MVB-385SD

Additional information

Model

MVB-385SD

Measurement Range

Acceleration: 0.5 to 199.9 m/s2 Velocity: 0.5 to 199.9 mm/s.

Other Function

Acceleration, Velocity: RMS, Peak, Max Hold

Sensor Output Interface

USB, RS-232 interface

Power Supply

Battery AAA x 6

Resolution

0.1

Accuracy

± (5% rdg + 2 d) @ 80 and 160Hz

Dimension

132 x 80 x 32 mm

Weight (Kg)

0.199

FEATURES

  • Applications for industrial vibration monitoring : All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance, misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed.
  • Frequency range 10 Hz – 1kHz, sensitivity relative meet IOS 2954.
  • Profressional vibration meter supply with vibration sensor & magnetic base, full set.
  • Metric & Imperial display unit.
  • Acceleration, Velocity measurement.
  • RMS, Max hold , Peak value measurement.
  • Max. Hold reset button, Zero button.
  • Wide frequency range.
  • Data hold button to freeze the desired reading.
  • Memory function to record maximum and minimum reading with recall.
  • Separate vibration probe with magnetic base, easy operation.
  • Real time SD memory card Datalogger, it Built-in Clock And Calenda, real time data recorder, sampling time set From 5 second to 3600 seconds.
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information(year/month/date/hour/minute/second) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity : 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM4/AAA( 1.5V ) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.